Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 805
Filtrar
1.
J Clin Med ; 13(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38610748

RESUMO

Background: Airway care interventions and prone positioning are used in critically ill patients with coronavirus disease 2019 (COVID-19) admitted to the intensive care unit (ICU) to improve oxygenation and facilitate mucus removal. At the onset of the COVID-19 pandemic, the decision-making process regarding the practice of airway care interventions and prone positioning was challenging. Objective: To provide an overview of the practice of airway care interventions and prone positioning during the second wave of the pandemic in the Netherlands. Method: Web-based survey design. Seventy ICU nurses, each representing one intensive care in the Netherlands, were contacted for participation. Potential items were generated based on a literature search and formulated by a multidisciplinary team. Questions were pilot tested for face and construct validity by four intensive care nurses from four different hospitals. Results: The response rate was 53/77 (69%). This survey revealed widespread use of airway care interventions in the Netherlands in COVID-19 patients, despite questionable benefits. Additionally, prone positioning was used in invasively and non-invasively ventilated patients. Conclusions: The use of airway care interventions and prone positioning is time consuming and comes with the production of waste. Further research is needed to assess the effectiveness, workload, and environmental impact of airway care interventions and prone positioning.

2.
Diagnostics (Basel) ; 14(7)2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38611592

RESUMO

Monitoring for thrombosis and hemolysis is crucial for patients under extracorporeal or mechanical circulatory support, but it can be costly. We investigated correlations between hemolysis index (HI) and plasma-free hemoglobin (PFH) levels on one hand, and between the HI and plasma lactate dehydrogenase (LDH) levels on the other, in critically ill patients with and without extracorporeal or mechanical circulatory support. Additionally, we calculated the cost reductions if monitoring through HI were to replace monitoring through PFH or plasma LDH. In a single-center study, HI was compared with PFH and plasma LDH levels in blood samples taken for routine purposes in critically ill patients with and without extracorporeal or mechanical circulatory support. A cost analysis, restricted to direct costs associated with each measurement, was made for an average 10-bed ICU. This study included 147 patients: 56 patients with extracorporeal or mechanical circulatory support (450 measurements) and 91 patients without extracorporeal or mechanical circulatory support (562 measurements). The HI correlated well with PFH levels (r = 0.96; p < 0.01) and poorly with plasma LDH levels (r = 0.07; p < 0.01) in patients with extracorporeal or mechanical circulatory support. Similarly, HI correlated well with PFH levels (r = 0.97; p < 0.01) and poorly with plasma LDH levels (r = -0.04; p = 0.39) in patients without extracorporeal or mechanical circulatory support. ROC analyses demonstrated a strong performance of HI, with the curve indicating excellent discrimination in the whole cohort (area under the ROC of 0.969) as well as in patients under ECMO or mechanical circulatory support (area under the ROC of 0.988). Although the negative predictive value of HI for predicting PFH levels > 10 mg/dL was high, its positive predictive value was found to be poor at various cutoffs. A simple cost analysis showed substantial cost reduction if HI were to replace PFH or plasma LDH for hemolysis monitoring. In conclusion, in this cohort of critically ill patients with and without extracorporeal or mechanical circulatory support, HI correlated well with PFH levels, but poorly with plasma LDH levels. Given the high correlation and substantial cost reductions, a strategy utilizing HI may be preferable for monitoring for hemolysis compared to monitoring strategies based on PFH or plasma LDH. The PPV of HI, however, is unacceptably low to be used as a diagnostic test.

3.
J Clin Med ; 13(5)2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38592057

RESUMO

(1) Background: SeptiCyte RAPID is a molecular test for discriminating sepsis from non-infectious systemic inflammation, and for estimating sepsis probabilities. The objective of this study was the clinical validation of SeptiCyte RAPID, based on testing retrospectively banked and prospectively collected patient samples. (2) Methods: The cartridge-based SeptiCyte RAPID test accepts a PAXgene blood RNA sample and provides sample-to-answer processing in ~1 h. The test output (SeptiScore, range 0-15) falls into four interpretation bands, with higher scores indicating higher probabilities of sepsis. Retrospective (N = 356) and prospective (N = 63) samples were tested from adult patients in ICU who either had the systemic inflammatory response syndrome (SIRS), or were suspected of having/diagnosed with sepsis. Patients were clinically evaluated by a panel of three expert physicians blinded to the SeptiCyte test results. Results were interpreted under either the Sepsis-2 or Sepsis-3 framework. (3) Results: Under the Sepsis-2 framework, SeptiCyte RAPID performance for the combined retrospective and prospective cohorts had Areas Under the ROC Curve (AUCs) ranging from 0.82 to 0.85, a negative predictive value of 0.91 (sensitivity 0.94) for SeptiScore Band 1 (score range 0.1-5.0; lowest risk of sepsis), and a positive predictive value of 0.81 (specificity 0.90) for SeptiScore Band 4 (score range 7.4-15; highest risk of sepsis). Performance estimates for the prospective cohort ranged from AUC 0.86-0.95. For physician-adjudicated sepsis cases that were blood culture (+) or blood, urine culture (+)(+), 43/48 (90%) of SeptiCyte scores fell in Bands 3 or 4. In multivariable analysis with up to 14 additional clinical variables, SeptiScore was the most important variable for sepsis diagnosis. A comparable performance was obtained for the majority of patients reanalyzed under the Sepsis-3 definition, although a subgroup of 16 patients was identified that was called septic under Sepsis-2 but not under Sepsis-3. (4) Conclusions: This study validates SeptiCyte RAPID for estimating sepsis probability, under both the Sepsis-2 and Sepsis-3 frameworks, for hospitalized patients on their first day of ICU admission.

4.
J Anesth Analg Crit Care ; 4(1): 21, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504319

RESUMO

BACKGROUND: Dissemination of medical practice and scientific information through social media (SoMe) by clinicians and researchers is increasing. Broad exposure of information can promote connectivity within the scientific community, overcome barriers to access to sources, increase debate, and reveal layperson perspectives and preferences. On the other hand, practices lacking scientific evidence may also be promoted, laypeople may misunderstand the professional message, and clinician may suffer erosion of professional status. The aim of this project was to enhance awareness and advise the anesthesia community and clinicians at large about the potential risks advocate for responsible use of SoMe to disseminate information related to medical practices and knowledge. METHODS: A modified Delphi process with prespecified consensus criteria was conducted among a multidisciplinary panel of experts, including anesthesiologists-intensivists, clinical psychologists, and forensic medicine specialists. Six items were identified: Ethics and deontological principles, the practice of sharing information via social media, legal aspects, psychological aspects, self-promotion, and criteria for appropriate dissemination. Statements and rationales were produced and subjected to blinded panelists' votes. After reaching consensus, a document was written which then underwent external review by experts uninvolved in the consensus process. The project was promoted by the Italian Society of Anesthesia Analgesia Resuscitation and Intensive Care (SIAARTI). RESULTS: Twelve statements were produced, and consensus was achieved for all. The panel concluded that the general principles guiding dissemination of professional information via SoMe must remain in line with the general principles of ethics, deontology, and scientific validity that guide the medical profession and science in general. Professional equity must be maintained while communicating via SoMe. Medical practices lacking support by scientific evidence should not be disseminated. Patients' informed consent must be obtained before dissemination of information, images, or data. Self-promotion must not be prioritized over any of these principles. CONCLUSIONS: When sharing medical practices and scientific information on SoMe, healthcare professionals are advised to act conscientiously and ethically. Local regulations should be adhered to. Institutional training on the potential risks and proper of SoMe for such purpose may contribute to preservation of professional integrity.

6.
Crit Care ; 28(1): 96, 2024 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-38521944

RESUMO

BACKGROUND: Acute respiratory distress syndrome (ARDS) poses challenges in early identification. Exhaled breath contains metabolites reflective of pulmonary inflammation. AIM: To evaluate the diagnostic accuracy of breath metabolites for ARDS in invasively ventilated intensive care unit (ICU) patients. METHODS: This two-center observational study included critically ill patients receiving invasive ventilation. Gas chromatography and mass spectrometry (GC-MS) was used to quantify the exhaled metabolites. The Berlin definition of ARDS was assessed by three experts to categorize all patients into "certain ARDS", "certain no ARDS" and "uncertain ARDS" groups. The patients with "certain" labels from one hospital formed the derivation cohort used to train a classifier built based on the five most significant breath metabolites. The diagnostic accuracy of the classifier was assessed in all patients from the second hospital and combined with the lung injury prediction score (LIPS). RESULTS: A total of 499 patients were included in this study. Three hundred fifty-seven patients were included in the derivation cohort (60 with certain ARDS; 17%), and 142 patients in the validation cohort (47 with certain ARDS; 33%). The metabolites 1-methylpyrrole, 1,3,5-trifluorobenzene, methoxyacetic acid, 2-methylfuran and 2-methyl-1-propanol were included in the classifier. The classifier had an area under the receiver operating characteristics curve (AUROCC) of 0.71 (CI 0.63-0.78) in the derivation cohort and 0.63 (CI 0.52-0.74) in the validation cohort. Combining the breath test with the LIPS does not significantly enhance the diagnostic performance. CONCLUSION: An exhaled breath metabolomics-based classifier has moderate diagnostic accuracy for ARDS but was not sufficiently accurate for clinical use, even after combination with a clinical prediction score.


Assuntos
Lesão Pulmonar , Pneumonia , Síndrome do Desconforto Respiratório , Humanos , Cuidados Críticos , Pulmão , Síndrome do Desconforto Respiratório/diagnóstico
7.
Diagnostics (Basel) ; 14(4)2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38396460

RESUMO

Serum biomarkers and lung ultrasound are important measures for prognostication and treatment allocation in patients with COVID-19. Currently, there is a paucity of studies investigating relationships between serum biomarkers and ultrasonographic biomarkers derived from lung ultrasound. This study aims to assess correlations between serum biomarkers and lung ultrasound findings. This study is a secondary analysis of four prospective observational studies in adult patients with COVID-19. Serum biomarkers included markers of epithelial injury, endothelial dysfunction and immune activation. The primary outcome was the correlation between biomarker concentrations and lung ultrasound score assessed with Pearson's (r) or Spearman's (rs) correlations. Forty-four patients (67 [41-88] years old, 25% female, 52% ICU patients) were included. GAS6 (rs = 0.39), CRP (rs = 0.42) and SP-D (rs = 0.36) were correlated with lung ultrasound scores. ANG-1 (rs = -0.39) was inversely correlated with lung ultrasound scores. No correlations were found between lung ultrasound score and several other serum biomarkers. In patients with COVID-19, several serum biomarkers of epithelial injury, endothelial dysfunction and immune activation correlated with lung ultrasound findings. The lack of correlations with certain biomarkers could offer opportunities for precise prognostication and targeted therapeutic interventions by integrating these unlinked biomarkers.

8.
Chest ; 165(2): 233-235, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38336431
9.
Eur J Anaesthesiol ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38385449

RESUMO

BACKGROUND: Lung protective ventilation is considered standard of care in the intensive care unit. However, modifying the ventilator settings can be challenging and is time consuming. Closed loop modes of ventilation are increasingly attractive for use in critically ill patients. With closed loop ventilation, settings that are typically managed by the ICU professionals are under control of the ventilator's algorithms. OBJECTIVES: To describe the effectiveness, safety, efficacy and workload with currently available closed loop ventilation modes. DESIGN: Systematic review of randomised clinical trials. DATA SOURCES: A comprehensive systematic search in PubMed, Embase and the Cochrane Central register of Controlled Trials search was performed in January 2023. ELIGIBILITY CRITERIA: Randomised clinical trials that compared closed loop ventilation with conventional ventilation modes and reported on effectiveness, safety, efficacy or workload. RESULTS: The search identified 51 studies that met the inclusion criteria. Closed loop ventilation, when compared with conventional ventilation, demonstrates enhanced management of crucial ventilator variables and parameters essential for lung protection across diverse patient cohorts. Adverse events were seldom reported. Several studies indicate potential improvements in patient outcomes with closed loop ventilation; however, it is worth noting that these studies might have been underpowered to conclusively demonstrate such benefits. Closed loop ventilation resulted in a reduction of various aspects associated with the workload of ICU professionals but there have been no studies that studied workload in sufficient detail. CONCLUSIONS: Closed loop ventilation modes are at least as effective in choosing correct ventilator settings as ventilation performed by ICU professionals and have the potential to reduce the workload related to ventilation. Nevertheless, there is a lack of sufficient research to comprehensively assess the overall impact of these modes on patient outcomes, and on the workload of ICU staff.

11.
J Crit Care ; 81: 154531, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38341938

RESUMO

PURPOSE: We investigated driving pressure (ΔP) and mechanical power (MP) and associations with clinical outcomes in critically ill patients ventilated for reasons other than ARDS. MATERIALS AND METHODS: Individual patient data analysis of a pooled database that included patients from four observational studies of ventilation. ΔP and MP were compared among invasively ventilated non-ARDS patients with sepsis, with pneumonia, and not having sepsis or pneumonia. The primary endpoint was ΔP; secondary endpoints included MP, ICU mortality and length of stay, and duration of ventilation. RESULTS: This analysis included 372 (11%) sepsis patients, 944 (28%) pneumonia patients, and 2040 (61%) patients ventilated for any other reason. On day 1, median ΔP was higher in sepsis (14 [11-18] cmH2O) and pneumonia patients (14 [11-18]cmH2O), as compared to patients not having sepsis or pneumonia (13 [10-16] cmH2O) (P < 0.001). Median MP was also higher in sepsis and pneumonia patients. ΔP, as opposed to MP, was associated with ICU mortality in sepsis and pneumonia patients. CONCLUSIONS: The intensity of ventilation differed between patients with sepsis or pneumonia and patients receiving ventilation for any other reason; ΔP was associated with higher mortality in sepsis and pneumonia patients. REGISTRATION: This post hoc analysis was not registered; the individual studies that were merged into the used database were registered at clinicaltrials.gov: NCT01268410 (ERICC), NCT02010073 (LUNG SAFE), NCT01868321 (PRoVENT), and NCT03188770 (PRoVENT-iMiC).


Assuntos
Pneumonia , Síndrome do Desconforto Respiratório , Sepse , Humanos , Respiração Artificial/efeitos adversos , Unidades de Terapia Intensiva , Pulmão , Síndrome do Desconforto Respiratório/terapia , Síndrome do Desconforto Respiratório/etiologia , Sepse/terapia , Sepse/etiologia
12.
Crit Care Med ; 52(5): 694-703, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38180043

RESUMO

OBJECTIVES: Deferred consent enables research to be conducted in the ICU when patients are unable to provide consent themselves, and there is insufficient time to obtain consent from surrogates before commencing (trial) treatment. The aim of this study was to evaluate how former ICU patients reflect on their participation in a study with deferred consent and examine whether their opinions are influenced by the quality of life (QoL) following hospital discharge. DESIGN: Survey study by questionnaire. SETTING: Eight ICUs in The Netherlands. PATIENTS: Former ICU patients who participated in the ICONIC trial, a multicenter randomized clinical trial that evaluated oxygenation targets in mechanically ventilated ICU patients. INTERVENTIONS: Participants enrolled in the ICONIC trial in one of the eight participating centers in The Netherlands received a questionnaire 6 months after randomization. The questionnaire included 12 close-ended questions on their opinion about the deferred consent procedure. QoL was measured using the EQ-5D-5L questionnaire. By calculating the EQ-5D index, patients were divided into four QoL quartiles, where Q1 reflects the lowest and Q4 is the highest. MEASUREMENTS AND MAIN RESULTS: Of 362 participants who were contacted, 197 responded (54%). More than half of the respondents (59%) were unaware of their participation in the ICONIC study. In total 61% were content with the deferred consent procedure, 1% were not content, 25% neutral, 9% did not know, and 9% answered "other." Those with a higher QoL were more likely to be content ( p = 0.02). In all QoL groups, the legal representative was the most often preferred individual to provide consent. CONCLUSIONS: Former ICU patients who participated in the ICONIC study often did not remember their participation but were predominantly positive regarding the use of deferred consent. Those with a higher QoL were most likely to be content.


Assuntos
Unidades de Terapia Intensiva , Qualidade de Vida , Humanos , Países Baixos
13.
Intensive Care Med ; 50(2): 234-246, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38294526

RESUMO

PURPOSE: The use of arterial partial pressure of carbon dioxide (PaCO2) as a target intervention to manage elevated intracranial pressure (ICP) and its effect on clinical outcomes remain unclear. We aimed to describe targets for PaCO2 in acute brain injured (ABI) patients and assess the occurrence of abnormal PaCO2 values during the first week in the intensive care unit (ICU). The secondary aim was to assess the association of PaCO2 with in-hospital mortality. METHODS: We carried out a secondary analysis of a multicenter prospective observational study involving adult invasively ventilated patients with traumatic brain injury (TBI), subarachnoid hemorrhage (SAH), intracranial hemorrhage (ICH), or ischemic stroke (IS). PaCO2 was collected on day 1, 3, and 7 from ICU admission. Normocapnia was defined as PaCO2 > 35 and to 45 mmHg; mild hypocapnia as 32-35 mmHg; severe hypocapnia as 26-31 mmHg, forced hypocapnia as < 26 mmHg, and hypercapnia as > 45 mmHg. RESULTS: 1476 patients (65.9% male, mean age 52 ± 18 years) were included. On ICU admission, 804 (54.5%) patients were normocapnic (incidence 1.37 episodes per person/day during ICU stay), and 125 (8.5%) and 334 (22.6%) were mild or severe hypocapnic (0.52 and 0.25 episodes/day). Forced hypocapnia and hypercapnia were used in 40 (2.7%) and 173 (11.7%) patients. PaCO2 had a U-shape relationship with in-hospital mortality with only severe hypocapnia and hypercapnia being associated with increased probability of in-hospital mortality (omnibus p value = 0.0009). Important differences were observed across different subgroups of ABI patients. CONCLUSIONS: Normocapnia and mild hypocapnia are common in ABI patients and do not affect patients' outcome. Extreme derangements of PaCO2 values were significantly associated with increased in-hospital mortality.


Assuntos
Dióxido de Carbono , Hipocapnia , Adulto , Humanos , Masculino , Feminino , Respiração Artificial , Hipercapnia/etiologia , Encéfalo
14.
Respir Care ; 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38296330

RESUMO

BACKGROUND: Endotracheal suctioning causes discomfort, is associated with adverse effects and is resource demanding. An artificial secretion removal method, known as an automated cough, has been developed, applying rapid, automated deflation and inflation of the endotracheal tube cuff during the inspiratory phase of mechanical ventilation. This method has been evaluated in the hands of researchers but not when used by attending nurses. The aim of this study was to explore the efficacy of the method over the course of patient management as part of routine care. METHODS: This prospective, longitudinal, interventional study recruited 28 subjects who were intubated and mechanically ventilated. For a maximum of 7 days and on clinical need for endotracheal suctioning, the automatic cough procedure was applied. Subjects were placed in a pressure regulated ventilation mode with elevated inspiratory pressure, and automated cuff deflation and inflation was performed 3 times, with this repeated if deemed necessary. Success was determined by removal of the clinical need for suctioning as determined by the attending nurse. Adverse effects were recorded. RESULTS: A total of 84 procedures were performed. In 54% of subjects the artificial cough procedure was successful on more than 70% of occasions, with 56% of all procedures considered successful. Ninety percent of all procedures were performed in spontaneously breathing subjects on pressure support ventilation with peak inspiratory pressures of 20 cmH2O. Rates of adverse events were similar to those seen in application of endotracheal suctioning. CONCLUSIONS: This study solely evaluated efficacy of an automated artificial cough procedure, illustrating the potential for reducing the need for endotracheal suctioning when applied by attending nurses in routine care.

15.
Am J Respir Crit Care Med ; 209(8): 973-986, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38240721

RESUMO

Rationale: The plasma lipidome has the potential to reflect many facets of the host status during severe infection. Previous work is limited to specific lipid groups or was focused on lipids as prognosticators.Objectives: To map the plasma lipidome during sepsis due to community-acquired pneumonia (CAP) and determine the disease specificity and associations with clinical features.Methods: We analyzed 1,833 lipid species across 33 classes in 169 patients admitted to the ICU with sepsis due to CAP, 51 noninfected ICU patients, and 48 outpatient controls. In a paired analysis, we reanalyzed patients still in the ICU 4 days after admission (n = 82).Measurements and Main Results: A total of 58% of plasma lipids were significantly lower in patients with CAP-attributable sepsis compared with outpatient controls (6% higher, 36% not different). We found strong lipid class-specific associations with disease severity, validated across two external cohorts, and inflammatory biomarkers, in which triacylglycerols, cholesterol esters, and lysophospholipids exhibited the strongest associations. A total of 36% of lipids increased over time, and stratification by survival revealed diverging lipid recovery, which was confirmed in an external cohort; specifically, a 10% increase in cholesterol ester levels was related to a lower odds ratio (0.84; P = 0.006) for 30-day mortality (absolute mortality, 18 of 82). Comparison with noninfected ICU patients delineated a substantial common illness response (57.5%) and a distinct lipidomic signal for patients with CAP-attributable sepsis (37%).Conclusions: Patients with sepsis due to CAP exhibit a time-dependent and partially disease-specific shift in their plasma lipidome that correlates with disease severity and systemic inflammation and is associated with higher mortality.


Assuntos
Infecções Comunitárias Adquiridas , Pneumonia , Sepse , Humanos , Lipidômica , Pneumonia/complicações , Sepse/complicações , Lipídeos , Índice de Gravidade de Doença , Unidades de Terapia Intensiva
16.
Nurs Crit Care ; 29(1): 219-225, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37144426

RESUMO

BACKGROUND: INTELLiVENT-adaptive support ventilation (ASV) is an automated closed-loop mode of invasive ventilation for use in critically ill patients. INTELLiVENT-ASV automatically adjusts, without the intervention of the caregiver, ventilator settings to achieve the lowest work and force of breathing. AIMS: The aim of this case series is to describe the specific adjustments of INTELLiVENT-ASV in patients with acute hypoxemic respiratory failure, who were intubated for invasive ventilation. STUDY DESIGN: We describe three patients with severe acute respiratory distress syndrome (ARDS) because of COVID-19 who received invasive ventilation in our intensive care unit (ICU) in the first year of the COVID-19 pandemic. RESULTS: INTELLiVENT-ASV could be used successfully, but only after certain adjustments in the settings of the ventilator. Specifically, the high oxygen targets that are automatically chosen by INTELLiVENT-ASV when the lung condition 'ARDS' is ticked had to be lowered, and the titration ranges for positive end expiratory pressure (PEEP) and inspired oxygen fraction (FiO2 ) had to be narrowed. CONCLUSIONS: The challenges taught us how to adjust the ventilator settings so that INTELLiVENT-ASV could be used in successive COVID-19 ARDS patients, and we experienced the benefits of this closed-loop ventilation in clinical practice. RELEVANCE TO CLINICAL PRACTICE: INTELLiVENT-ASV is attractive to use in clinical practice. It is safe and effective in providing lung-protective ventilation. A closely observing user always remains needed. INTELLiVENT-ASV has a strong potential to reduce the workload associated with ventilation because of the automated adjustments.


Assuntos
COVID-19 , Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Humanos , Pandemias , COVID-19/terapia , Pulmão , Respiração Artificial , Insuficiência Respiratória/terapia , Síndrome do Desconforto Respiratório/terapia , Oxigênio
17.
Crit Care Med ; 52(2): e100-e104, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-37962157

RESUMO

OBJECTIVES: To assess the effect of incorporating bilateral abnormalities as detected by lung ultrasound (LUS) in the Kigali modification and the New Global definition of acute respiratory distress syndrome (ARDS) on the occurrence rate of ARDS. DESIGN: Post hoc analysis of a previously published prospective cohort study. SETTING: An academic mixed medical-surgical ICU. PATIENTS: The original study included critically ill adults with any opacity on chest radiography in whom subsequent LUS was performed. Patients with ARDS according to the Berlin definition, COVID-19 patients and patients with major thorax trauma were excluded. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: LUS was performed within 24 hours of chest radiography and the presence of unilateral and bilateral abnormalities on LUS and chest radiograph (opacities) was scored. Subsequently, the Kigali modification and the New Global definition of ARDS were applied by two independent researchers on the patients with newly found bilateral opacities. Of 120 patients, 116 were included in this post hoc analysis. Thirty-three patients had bilateral opacities on LUS and unilateral opacities on chest radiograph. Fourteen of these patients had ARDS according to the Kigali modification and 12 had ARDS according to the New Global definition. The detected LUS patterns were significantly different between patients with and without ARDS ( p = 0.004). An A-profile with a positive PosteroLateral Alveolar and/or Pleural Syndrome was most prevalent in patients without ARDS, whereas heterogeneous and mixed A, B, and C patterns were most prevalent in patients with ARDS. CONCLUSION: The addition of bilateral abnormalities as detected by LUS to the Kigali modification and the New Global definition increases the occurrence rate of the ARDS. The nomenclature for LUS needs to be better defined as LUS patterns differ between patients with and without ARDS. Incorporating well-defined LUS criteria can increase specificity and sensitivity of new ARDS definitions.


Assuntos
Pulmão , Síndrome do Desconforto Respiratório , Adulto , Humanos , Estudos Prospectivos , Ruanda , Pulmão/diagnóstico por imagem , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/epidemiologia , Tórax , Ultrassonografia
18.
Eur J Anaesthesiol ; 41(1): 34-42, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37972930

RESUMO

BACKGROUND: Qualitative data on the opinions of anaesthesiologists regarding the impact of peri-operative night-time working conditions on patient safety are lacking. OBJECTIVES: This study aimed to achieve in-depth understanding of anaesthesiologists' perceptions regarding the impact of night-time working conditions on peri-operative patient safety and actions that may be undertaken to mitigate perceived risks. DESIGN: Qualitative analysis of responses to two open-ended questions. SETTING: Online platform questionnaire promoted by the European Society of Anaesthesiology and Intensive Care (ESAIC). PARTICIPANTS: The survey sample consisted of an international cohort of anaesthesiologists. MAIN OUTCOME MEASURES: We identified and classified recurrent themes in the responses to questions addressing perceptions regarding (Q1) peri-operative night-time working conditions, which may affect patient safety and (Q2) potential solutions. RESULTS: We analysed 2112 and 2113 responses to Q1 and Q2, respectively. The most frequently reported themes in relation to Q1 were a perceived reduction in professional performance accompanied by concerns regarding the possible consequences of work with fatigue (27%), and poor working conditions at night-time (35%). The most frequently proposed solutions in response to Q2 were a reduction of working hours and avoidance of 24-h shifts (21%), an increase in human resources (14%) and performance of only urgent or emergency surgeries at night (14%). CONCLUSION: Overall, the surveyed anaesthesiologists believe that workload-to-staff imbalance and excessive working hours were potential bases for increased peri-operative risk for their patients, partly because of fatigue-related medical errors during night-time work. The performance of nonemergency elective surgical cases at night and lack of facilities were among the reported issues and potential targets for improvement measures. Further studies should investigate whether countermeasures can improve patient safety as well as the quality of life of anaesthesia professionals. Regulations to improve homogeneity, safety, and quality of anaesthesia practice at night seem to be urgently needed.


Assuntos
Anestesiologia , Qualidade de Vida , Humanos , Anestesiologistas , Inquéritos e Questionários , Fadiga
19.
Am J Respir Crit Care Med ; 209(7): 829-839, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38099833

RESUMO

Rationale: Pneumonia is a frequent and feared complication in intubated critically ill patients. Tissue concentrations of antimicrobial drugs need to be sufficiently high to treat the infection and also prevent development of bacterial resistance. It is uncertain whether pulmonary inflammation and injury affect antimicrobial drug penetration into lung tissue.Objectives: To determine and compare tissue and BAL fluid concentrations of ceftaroline fosamil and linezolid in a model of unilateral acute lung injury in pigs and to evaluate whether dose adjustment is necessary to reach sufficient antimicrobial concentrations in injured lung tissue.Methods: After induction of unilateral acute lung injury, ceftaroline fosamil and linezolid were administered intravenously. Drug concentrations were measured in lung tissue through microdialysis and in blood and BAL fluid samples during the following 8 hours. The primary endpoint was the tissue concentration area under the concentration curve in the first 8 hours (AUC0-8 h) of the two antimicrobial drugs.Measurements and Main Results: In 10 pigs, antimicrobial drug concentrations were higher in inflamed and injured lung tissue compared with those in uninflamed and uninjured lung tissue (median ceftaroline fosamil AUC0-8 h [and interquartile range] = 26.7 mg ⋅ h ⋅ L-1 [19.7-39.0] vs. 16.0 mg ⋅ h ⋅ L-1 [13.6-19.9], P = 0.02; median linezolid AUC0-8 h 76.0 mg ⋅ h ⋅ L-1 [68.1-96.0] vs. 54.6 mg ⋅ h ⋅ L-1 [42.7-60.9], P = 0.01), resulting in a longer time above the minimal inhibitory concentration and in higher peak concentrations and dialysate/plasma ratios. Penetration into BAL fluid was excellent for both antimicrobials, but without left-to-right differences (ceftaroline fosamil, P = 0.78; linezolid, P = 1.00).Conclusions: Tissue penetration of two commonly used antimicrobial drugs for pneumonia is enhanced by early lung tissue inflammation and injury, resulting in longer times above the minimal inhibitory concentration. Thus, lung tissue inflammation ameliorates antimicrobial drug penetration during the acute phase.


Assuntos
Lesão Pulmonar Aguda , Anti-Infecciosos , Pneumonia , Humanos , Animais , Suínos , Linezolida/uso terapêutico , Antibacterianos/efeitos adversos , Anti-Infecciosos/uso terapêutico , 60602 , Pneumonia/tratamento farmacológico , Pneumonia/induzido quimicamente , Inflamação/tratamento farmacológico , Inflamação/induzido quimicamente , Pulmão , Lesão Pulmonar Aguda/tratamento farmacológico , Lesão Pulmonar Aguda/induzido quimicamente
20.
J Clin Anesth ; 92: 111242, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37833194

RESUMO

STUDY OBJECTIVE: We aimed to characterize intra-operative mechanical ventilation with low or high positive end-expiratory pressure (PEEP) and recruitment manoeuvres (RM) regarding intra-tidal recruitment/derecruitment and overdistension using non-linear respiratory mechanics, and mechanical power in obese surgical patients enrolled in the PROBESE trial. DESIGN: Prospective, two-centre substudy of the international, multicentre, two-arm, randomized-controlled PROBESE trial. SETTING: Operating rooms of two European University Hospitals. PATIENTS: Forty-eight adult obese patients undergoing abdominal surgery. INTERVENTIONS: Intra-operative protective ventilation with either PEEP of 12 cmH2O and repeated RM (HighPEEP+RM) or 4 cmH2O without RM (LowPEEP). MEASUREMENTS: The index of intra-tidal recruitment/de-recruitment and overdistension (%E2) as well as airway pressure, tidal volume (VT), respiratory rate (RR), resistance, elastance, and mechanical power (MP) were calculated from respiratory signals recorded after anesthesia induction, 1 h thereafter, and end of surgery (EOS). MAIN RESULTS: Twenty-four patients were analyzed in each group. PEEP was higher (mean ± SD, 11.7 ± 0.4 vs. 3.7 ± 0.6 cmH2O, P < 0.001) and driving pressure lower (12.8 ± 3.5 vs. 21.7 ± 6.8 cmH2O, P < 0.001) during HighPEEP+RM than LowPEEP, while VT and RR did not differ significantly (7.3 ± 0.6 vs. 7.4 ± 0.8 ml∙kg-1, P = 0.835; and 14.6 ± 2.5 vs. 15.7 ± 2.0 min-1, P = 0.150, respectively). %E2 was higher in HighPEEP+RM than in LowPEEP following induction (-3.1 ± 7.2 vs. -12.4 ± 10.2%; P < 0.001) and subsequent timepoints. Total resistance and elastance (13.3 ± 3.8 vs. 17.7 ± 6.8 cmH2O∙l∙s-2, P = 0.009; and 15.7 ± 5.5 vs. 28.5 ± 8.4 cmH2O∙l, P < 0.001, respectively) were lower during HighPEEP+RM than LowPEEP. Additionally, MP was lower in HighPEEP+RM than LowPEEP group (5.0 ± 2.2 vs. 10.4 ± 4.7 J∙min-1, P < 0.001). CONCLUSIONS: In this sub-cohort of PROBESE, intra-operative ventilation with high PEEP and RM reduced intra-tidal recruitment/de-recruitment as well as driving pressure, elastance, resistance, and mechanical power, as compared with low PEEP. TRIAL REGISTRATION: The PROBESE study was registered at www. CLINICALTRIALS: gov, identifier: NCT02148692 (submission for registration on May 23, 2014).


Assuntos
Respiração com Pressão Positiva , Respiração Artificial , Adulto , Humanos , Estudos Prospectivos , Volume de Ventilação Pulmonar , Obesidade/complicações , Obesidade/cirurgia , Mecânica Respiratória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...